ensure that the appropriate manager events are sent in all of the places where

alarms are detected or cleared (issue #6866, flefoll)


git-svn-id: https://origsvn.digium.com/svn/asterisk/branches/1.2@25123 65c4cc65-6c06-0410-ace0-fbb531ad65f3
1.2
Russell Bryant 19 years ago
parent 0f643c18be
commit eb19888db5

@ -6340,11 +6340,17 @@ static int handle_init_event(struct zt_pvt *i, int event)
i->inalarm = 0;
ast_log(LOG_NOTICE, "Alarm cleared on channel %d\n", i->channel);
break;
manager_event(EVENT_FLAG_SYSTEM, "AlarmClear",
"Channel: %d\r\n", i->channel);
case ZT_EVENT_ALARM:
i->inalarm = 1;
res = get_alarms(i);
ast_log(LOG_WARNING, "Detected alarm on channel %d: %s\n", i->channel, alarm2str(res));
/* fall thru intentionally */
manager_event(EVENT_FLAG_SYSTEM, "Alarm",
"Alarm: %s\r\n"
"Channel: %d\r\n",
alarm2str(res), i->channel);
case ZT_EVENT_ONHOOK:
if (i->radio) break;
/* Back on hook. Hang up. */