When we receive a known alarm, make sure that the unknown alarm flag is not still

set to make sure that when we come back out of alarm, it gets reported in the log
and manager interface (after discussion with tzafrir on the -dev list)


git-svn-id: https://origsvn.digium.com/svn/asterisk/branches/1.4@104591 65c4cc65-6c06-0410-ace0-fbb531ad65f3
1.4
Russell Bryant 18 years ago
parent bb7aa0e4bc
commit 54eaddd028

@ -3841,6 +3841,8 @@ static struct ast_frame *zt_handle_event(struct ast_channel *ast)
if (!strcasecmp(alarm_str, "No Alarm") || !strcasecmp(alarm_str, "Unknown Alarm")) {
p->unknown_alarm = 1;
break;
} else {
p->unknown_alarm = 0;
}
ast_log(LOG_WARNING, "Detected alarm on channel %d: %s\n", p->channel, alarm_str);
@ -6710,6 +6712,8 @@ static int handle_init_event(struct zt_pvt *i, int event)
if (!strcasecmp(alarm_str, "No Alarm") || !strcasecmp(alarm_str, "Unknown Alarm")) {
i->unknown_alarm = 1;
break;
} else {
i->unknown_alarm = 0;
}
ast_log(LOG_WARNING, "Detected alarm on channel %d: %s\n", i->channel, alarm_str);

Loading…
Cancel
Save